Feedback

All About Fire Rated Products

Shoemaker fire rated products include T-Bars, fire dampers for the wall and floor and fire/smoke dampers. Each fire product has a UL listing and the fire dampers and fire/smoke dampers also have CFSM California State Fire Marshall listing. Check out Shoemaker's fire rated products to find what you need for your project.

Fire Rated Subgroups

T-Bar

T-Bar

  • Fire rated T-Bars are available in supply and return.
  • Fire rated T-bars consist of the T-Bar, ceiling radiation damper, and thermal blanket.
  • Fire rated T-Bars have a UL listing and are rated for 3 hours.
  • Series include: 104-FR, 700CB-FR, 700DVD-FR, 700MA-FR, 780-FR, 825CB-FR, 825MA-FR, 830-FR, HL-FR, HVD-FR, HVL-FR
Fire Damper

Fire Damper

  • Fire dampers are available in a variety of sizes, including fractional, exact OD, and exact ID.
  • Fire dampers are available with a 2 1/4" or 4 1/4" roll formed frame, in or out of airstream, 1 1/2 hour or 3 hour rated, and as dynamic and true round.
  • Fire dampers are UL and CFSM California State Fire Marshall listed.
  • Series include: 2502, 2534, 2550, 2561, 2563, 2565, 2602, 2634, 2650, 2652, 2661, 2663, 2665, 2800
Fire/Smoke Damper

Fire/Smoke Damper

  • Fire/smoke dampers are class 2 - low leakage but are also available as class 1 - ultra low leakage.
  • Fire/smoke dampers are available with a 120V or 24V actuator.
  • Fire/smoke dampers are UL and CFSM California State Fire Marshall listed.
  • Series include: CFSD, FSD

FAQ

Q: I have a competitor’s fire rated product that I am trying to match. How can I find out what the Shoemaker Mfg. equivalent is?


A: Use our handy Cross Reference.

Q: I need a ceiling radiation damper. Does Shoemaker offer these?


A: Shoemaker does offer a selection of ceiling radiation dampers. Please check out these Radiation Dampers.

Q: The 700CB and 700CB-FR look similar. What is the difference?


A: The 700CB is a T-Bar diffuser. The 700CB-FR is a fire rated T-Bar diffuser. Shoemaker adds a ceiling radiation damper and TTB to the 700CB and has this tested to make it fire rated.

Q: I need a fire rated T-Bar but the T-Bar I found on your website is not fire rated. Can I just add the ceiling radiation damper and TTB to the T-Bar I want to make it fire rated?


A: Shoemaker products listed as fire rated are tested and given a UL listing. So, unfortunately, just adding the ceiling radiation damper and TTB will not make the T-Bar fire rated. You will need to check with your inspector to see if this will work as Shoemaker cannot decide this.